The Honeywell LFH20-2B65 is designed to measure relative humidity and temperature inside air ducts. It combines an active capacitive humidity sensor and an active temperature sensor with an additional passive NTC 20kΩ temperature sensing element.
It is commonly used in HVAC systems, air handling units, ventilation systems, and building automation applications.
|
Parameter |
Description |
|---|---|
|
Brand |
Honeywell |
|
Model |
LFH20-2B65 |
|
Product Type |
Duct Humidity and Temperature Transmitter |
|
Humidity Measuring Principle |
Capacitive |
|
Humidity Measuring Range |
10–90% RH |
|
Humidity Output |
0–10 VDC |
|
Temperature Measuring Range |
-5 to +55°C |
|
Temperature Output |
0–10 VDC |
|
Additional Temperature Sensor |
NTC 20kΩ |
|
NTC Nominal Resistance |
20 kΩ at 25°C |
|
NTC Accuracy |
±0.2°C at 25°C |
|
Supply Voltage |
15–35 VDC or 24 VAC ±20% |
|
Current Consumption |
Approx. 5 mA DC / 13 mA AC |
|
Humidity Accuracy |
±3% RH (30–70% RH at 20°C) |
|
Temperature Accuracy |
±0.3°C at 20°C |
|
Probe Length |
Approx. 230 mm |
|
Protection Rating |
IP65 housing / IP40 sensing part |
|
Operating Temperature |
-5 to +55°C |
|
Mounting Type |
Duct Mount |
Dual Measurement: Monitors both relative humidity and temperature.
Capacitive Humidity Sensor: Provides reliable humidity measurement.
Dual Temperature Sensing: Includes an active 0–10 V temperature output and an additional passive NTC 20kΩ sensor.
Analog Output: Easily integrates with HVAC controllers and building management systems.
Compact Duct Design: Designed for direct installation into air ducts.
Protective Housing: Provides IP65 protection for the enclosure.
HVAC air conditioning systems
Air handling units
Ventilation and exhaust air monitoring
Building management systems (BMS)
Humidity control systems
Condensation prevention
Industrial environmental monitoring
Install the probe in a suitable position inside the air duct.
Verify the 24 VAC or DC power supply requirements.
Connect the analog outputs according to the controller specifications.
Connect the additional NTC 20kΩ sensor to a compatible temperature input.
Avoid condensation and direct water exposure on the sensing element.
Follow the manufacturer's wiring and installation instructions.
Combined humidity and temperature measurement
Additional passive NTC 20kΩ temperature output
Compatible with HVAC and building automation systems
Easy duct installation