General Information
- Manufacturer: Honeywell Analytics
- Order number: 05704-A-0146
- Model: 5704F Four Channel Fire Control Card
- System: System 57 modular fire and gas control rack
- Function: Controls, displays and alarms up to four independent conventional fire detection zones
- Input devices: Compatible with most flame, smoke and heat detectors and manual call points
- Control method: Microprocessor controlled, configuration stored in EEPROM
- Related interface cards: Hex Relay Interface Card 05704-A-0123, Relay Interface Assembly 05704-A-0133
- Related rack panel: 5704FS Fire Status Panel 05704-A-0148
- Form factor: 3U height, one-inch wide System 57 card
- Installation: Rack mounted in a System 57 19-inch sub-rack or cabinet
Key Specifications
- Fire zone inputs: 4 independent conventional circuits
- Loop current open circuit: 0 to 3 mA
- Loop current normal: 3 to 10 mA
- Loop current fire alarm: 10 to 30 mA
- Loop current short circuit: 30 to 50 mA and above
- System supply: 21 to 32 VDC rack supply
- Loop voltage limiter: Built-in, limits maximum loop voltage to +24 V
- Current sense resistor: 220 ohm
- Barrier equivalent: Link selectable 330 ohm resistor for use without external IS barrier
- End of line resistor: Typical 5.1 k ohm per loop
- Switched DC outputs: 2 fault-monitored alarm output circuits
- Switched output current limit: Max. 1 A per output
- Volt-free relay outputs: 6 relays with standard Hex Relay Interface Card; up to 16 relays with Relay Interface Assembly
- Relay contact rating: 5 A at 110/250 VAC non-inductive, 5 A at 32 VDC non-inductive
- Field terminals: Up to 2.5 mm², 14 AWG
- Remote input: Common rack 3-function remote input for Reset, Mute and Test
- Front indication: Per-zone fire and fault LEDs, card fault LED, status push-button
- Relay operation: Selectable latching or non-latching, energised or de-energised
- Card dimensions: Approx. 17.2 x 2.5 x 13.2 cm
- Card weight: Approx. 0.16 kg; shipping weight approx. 1.5 kg, supplier data
- Operating temperature: -5 to +55 °C per System 57 product data
- Storage temperature: -25 to +55 °C
- Humidity: 0 to 90% RH, non-condensing
- Rack backplane current limit: Max. 8 A total
Features and Advantages
- Four conventional fire zones per one-inch card allow high-density fire detection in a compact System 57 rack
- Current-loop monitoring detects open circuit, normal, alarm and short-circuit conditions on each zone
- Per-zone high intensity LEDs show fire alarm and zone fault status directly at the card
- Two line-monitored switched DC outputs drive sounders, beacons or other notification appliances with fault supervision
- Volt-free relay outputs provide flexible alarm, fault, inhibit and zone contacts to external panels or PLCs
- Relay logic can be configured latching or non-latching and energised or de-energised to match the fire system design
- Microprocessor supervision continuously checks detector signals, card electronics and output status
- EEPROM retains zone configuration, alarm logic and relay assignment after power loss
- Fire and gas control cards can be freely mixed in the same System 57 rack
- Up to 60 fire zones can be monitored per 19-inch rack when fire cards are installed
- The 5704FS status panel provides common rack display, audible sounder and shared fire system push-buttons
- Compatible with loop-powered two-wire detectors, separately powered flame detectors and voltage-free contact detectors
- Modular card replacement supports maintenance and future system expansion
Typical Applications
- Industrial conventional fire detection panels in oil and gas plants
- Refineries, chemical processing and storage facilities
- Power generation, turbine rooms and compressor stations
- Manufacturing plants, warehouses and process areas
- Flame, smoke and heat detector zone monitoring
- Manual call point circuits in industrial buildings
- Mixed fire and gas safety systems built on the System 57 platform
- Retrofit and spare card replacement for installed Honeywell System 57 fire panels
Precautions and Notes
- Confirm this card is intended for fire zones; do not use 5704F cards for catalytic LEL or 4 to 20 mA gas detector channels
- Match the interface card to the fire detector type: Hex Relay Interface Card 05704-A-0123 or Relay Interface Assembly 05704-A-0133
- Each rack containing a 5704F card requires the matching 5704FS Fire Status Panel 05704-A-0148
- Fit the correct end of line resistor, typically 5.1 k ohm, at the end of each detector loop
- Verify IS barrier selection and input link settings when connecting intrinsically safe field devices
- Check the 330 ohm barrier equivalent link and earth leakage link settings against the installation manual
- Do not exceed the 1 A switched DC output limit or the 8 A rack backplane current loading
- Relay contact ratings apply to non-inductive loads; use external protection and contactor relays for inductive or high-current loads
- Keep detector loop quiescent current within the zone limit when multiple detectors are connected in parallel
- Connect cable screen, armour or braid to protective earth at cabinet entry; avoid screen tails inside the cabinet
- Verify loop polarity at IN+ and IN-; loop current flows from IN+ and returns via IN-
- Remote Reset, Mute and Test functions must be wired and configured according to the rack and status panel design
- Maintain the rated -5 to +55 °C operating range and avoid condensation in the cabinet
- Remove rack power before inserting or removing cards to protect the backplane and connectors
- Confirm detector type, EOL resistor, relay assignment and alarm logic during engineering commissioning
- Weight, dimensions and shipping data are supplier values where not printed on the official manual; verify against the delivered card
- For new projects, confirm current Honeywell Analytics fire and gas control system compatibility and spare part availability