banner
Home Honeywell

HONEYWELL 05701-A-0302CPU Gas Detection Controller

HONEYWELL 05701-A-0302CPU Gas Detection Controller

HONEYWELL 05701-A-0302CPU Gas Detection Controller

  • Item NO.:

    05701-A-0302CPU
  • Payment:

    T/T
  • Price:

    $1280
  • Product Origin:

    USA
  • Color:

    NEW
  • Product weight:

    0.35kg
  • Lead Time:

    In stock

We will arrange delivery within 3-5 days after receiving the payment.

Our express delivery: DHL and FedEx.

Quality packing for each product

Destination country all taxes & duty to be paid by buyer

Only part of the brand and model, if you have other product needs, please contact us.

General Information

  • Manufacturer: Honeywell Analytics
  • Order number: 05701-A-0302
  • Product type: System 57 / 5701 single channel control card, catalytic sensor version
  • Sensor drive module: Factory fitted 05701-A-0284 catalytic Sensor Drive Module
  • System: Rack-mounted System 57 gas detection control system
  • Function: Sensor power supply, signal conditioning, gas reading display, alarm comparison, fault supervision and channel status indication
  • Configuration: Microprocessor controlled, setup stored in EEPROM
  • Optional module: Analogue Output Module 05701-A-0285, isolated 0 to 20 mA or 4 to 20 mA loop
  • Related version: 05701-A-0301 is the 4 to 20 mA control card; this 0302 version is for catalytic LEL sensors
  • Installation: System 57 rack backplane slot, secured with card retaining screws

Key Specifications

  • DC supply: 18 to 32 VDC
  • Power consumption: 3.75 W typical, including catalytic sensor
  • Sensor type: Catalytic combustible LEL bridge sensor, bridge drive at 200 mA
  • Display: 25-segment analog bar, four-character digital reading, four-character message display, power and card select icons
  • Alarm LEDs: A1, A2, A3 red gas alarm LEDs; Fault and Inhibit amber LEDs
  • Front push-button: Alarm reset and card select
  • Alarm setpoint resolution: 1% fsd steps
  • Linearity: ±1% fsd
  • Repeatability: ±1% fsd
  • Electronic drift: Less than ±2% over 6 months
  • Remote inputs: RESET and INHIBIT, each configurable active high or active low
  • Remote input switching level: Approx. +2 V relative to system 0 V
  • Remote input drive current: Less than 5 mA
  • Remote input maximum voltage: 32 V
  • Optional analogue output: Isolated current loop, 0 to 20 mA or 4 to 20 mA, loop voltage up to 40 V
  • Relay outputs: Provided by separate Field Interface or Relay Cards; contact rating 5 A at 110/250 VAC non-inductive, 5 A at 32 VDC non-inductive
  • Field terminal cross section: Up to 2.5 mm², 14 AWG
  • Card dimensions: Height 112 mm, width 25 mm, depth 170 mm
  • Card weight: Approx. 165 g, supplier data
  • Operating temperature: -5 to +55 °C
  • Storage temperature: -25 to +55 °C
  • Humidity: 0 to 90% RH, non-condensing
  • EMC: EN50270 per System 57 product data

Features and Advantages

  • Dedicated channel control for one catalytic combustible gas detector with matched bridge drive and signal conditioning
  • Front analog bar and digital message display show live reading and channel status at a glance
  • Three configurable A1, A2 and A3 alarm levels support staged warning and alarm strategies
  • Fault supervision detects sensor hardware failure, out-of-limits signal, card hardware or software fault
  • Inhibit mode can be applied locally, remotely or automatically during start-up and engineering functions
  • EEPROM retains channel configuration, alarm setpoints and calibration data after power loss
  • Self-validation checks circuit components, software operation and backplane communications
  • Optional isolated analogue output transmits the live reading to recorders, PLCs or remote monitoring systems
  • Remote reset and inhibit inputs integrate the channel into plant safety and maintenance procedures
  • Card-based rack design allows channel replacement and system expansion within the System 57 cabinet
  • Sensor drive module and control card are matched at factory for catalytic sensor compatibility
  • Clear LED and message diagnostics speed up commissioning, calibration and troubleshooting

Typical Applications

  • Combustible LEL gas detection in oil and gas processing plants
  • Chemical and petrochemical storage, pumping and processing areas
  • Refineries, tank farms and compressor stations
  • Painting, coating and solvent vapor areas
  • Power generation, turbine rooms and fuel storage zones
  • Industrial boiler rooms, heating plant and combustion equipment monitoring
  • System 57 fixed gas detection panels requiring catalytic sensor channel control
  • Hazardous area plant monitoring with sensors in the field and control cards mounted in the cabinet

Precautions and Notes

  • Confirm the card matches the sensor type: 05701-A-0302 is for catalytic sensors; use 05701-A-0301 for 4 to 20 mA transmitters
  • This card controls one detection channel; it does not replace the rack Engineering Card, power supply card or master alarm relay card
  • The card mounts in a System 57 rack and requires the correct backplane, DC input card, field interface or relay card arrangement
  • Do not apply more than 32 V to remote inhibit or reset inputs; overvoltage can permanently damage the card
  • Do not connect the optional analogue output to a loop voltage above 40 V
  • Verify relay card type and contact rating before switching mains or inductive loads; AC relay supplies should be fused at max. 5 A
  • Alarm relay energisation mode, normally energised or normally de-energised, must be checked in the configuration sheet or engineering software
  • Fault relay is permanently configured for energised operation in the non-fault state; alarm relay behavior is configurable
  • Remote active low inputs must not be left unconnected; follow active high or active low wiring rules in the manual
  • Keep sensor cable screen and armouring correctly earthed; where the sensor is locally earthed, connect the screen at one end only to avoid earth loops
  • Configure alarm thresholds, rising or falling action, analog output range and channel labels through the Engineering Card or engineering interface
  • Perform zero, span, calibration and alarm test procedures according to the System 57 manual and sensor service schedule
  • Maintain the rated -5 to +55 °C operating range and avoid condensation; storage range is -25 to +55 °C
  • Remove power before inserting or removing cards to protect the backplane and electronics
  • Calibration gas, sensor type and gas range must match the channel configuration and detector rating
  • Weight and service conditions are supplier data where not shown on the official manual; confirm against the delivered card label
  • For new systems, verify current Honeywell Analytics gas detection controller and detector compatibility before selection
                                    •  

Please make an inquiry for more models

Honeywell H7080B3273

Honeywell 808630.1

Honeywell CSNS300M-500

Honeywell FS24XP-ANGXX

Honeywell CSNS300M-002S

Honeywell RA890G1260/U

Honeywell 50119638-001

Honeywell ST800 HNS50049911-001

Honeywell TK-FTEB01 51309512-175

Honeywell CSNX25

Honeywell EX-AR20

Honeywell MPD-UTCB1

Honeywell 6PA5-EX

Honeywell 2MLR-CPUH

Honeywell HNS50049911-001

Honeywell AWM43300V

Honeywell ES06F-1/2A

Honeywell TN3801

Honeywell TA3840C

Honeywell DR45AT-1100-00-000-0-0000

Honeywell FC-SCNT01

Honeywell DC300K-E-0A0-10-0000-0

Honeywell 2106B2310

Honeywell 2108B2101H

Honeywell XFL522

Honeywell V5011R1034

Honeywell EC7850A1080

Honeywell DKW972-N

Honeywell C6045D1043

Honeywell A4021A1002

Honeywell LSQ051

Honeywell 2108B2003H

Honeywell DC330B-C00-000-30-000000-00-0

Honeywell UDC-3300

Honeywell SPXCDULNTXF

Honeywell UDC2500 DC2500-CE-0A00-200-00000-00-0

Honeywell 11002000

Honeywell 1NT1-3D

Honeywell CC-TAOX11 51308353-175

Honeywell r404a

Honeywell LSZ51B

Honeywell MU-PLAM02 51304362-150

Honeywell GSAC01A1B

Honeywell 2104B2131 RX MID

Honeywell VRS 3010S20

Honeywell MS4609F1210

Honeywell LS2A4L

Honeywell L6188A2036

Honeywell 8C-PAONAI

Honeywell 190971E

Honeywell STG974

Honeywell 2110B3707

Honeywell 1020-CL 311000

Honeywell MS4604F1210

Honeywell MS4620F1203

Honeywell BZE7-2RN-PG

Honeywell 51305482-105

Honeywell 900PSM-0200

Honeywell 802371

Honeywell 805590

Honeywell evoQ4

Honeywell 900S75S-0460

Honeywell R4343-E1014

Honeywell MPD-AMCB

Honeywell XLS3000

Honeywell 008-1161-000

Honeywell MU-PLAM02 51304362-100

Honeywell EXD-Q-3

Honeywell 900P02-0201

Honeywell BXA3K-1A1

Honeywell UDC3200-CE-100R-200-00000

Honeywell DC2800-CE-0S0-200-000-00-0

Honeywell 51309153-275

Honeywell STT25S-0-ENE-T00-S00-0D0-3D

Honeywell STD820-E1AS4AS-1-C-CHE-11C-B-30A6-F1+0000

Honeywell TH5220D1003

Honeywell SDO-0824

Honeywell 10216/2/1

Honeywell 2MLF-DC8A

 

Other best-selling products:

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

05701-A-0301
HONEYWELL 05701-A-0301 Single Channel Control Card

HONEYWELL 05701-A-0301 Single Channel Control Card

Details
8C-PDILA1
HONEYWELL 8C-PDILA1 Digital Input Module

HONEYWELL 8C-PDILA1 Digital Input Module

Details
CC-PAIN01
HONEYWELL CC-PAIN01 Analog Input Module

HONEYWELL CC-PAIN01 Analog Input Module

Details
620-0036
HONEYWELL 620-0036 AC Power Module

HONEYWELL 620-0036 AC Power Module

Details
 05704-A-0145
HONEYWELL 05704-A-0145 Four-channel control card

HONEYWELL 05704-A-0145 Four-channel control card

Details
CC-PUIO31
HONEYWELL CC-PUIO31 Universal Input Output Module

HONEYWELL CC-PUIO31 Universal Input Output Module

Details
51199929-100
HONEYWELL 51199929-100 Power Module

HONEYWELL 51199929-100 Power Module

Details
CC-PDIL01
HONEYWELL CC-PDIL01 Digital Input Module

HONEYWELL CC-PDIL01 Digital Input Module

Details

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Contact Us:justwellautomation@qq.com

Home

Products

whatsApp

contact