General Information
- Manufacturer: Honeywell Analytics
- Order number: 05701-A-0302
- Product type: System 57 / 5701 single channel control card, catalytic sensor version
- Sensor drive module: Factory fitted 05701-A-0284 catalytic Sensor Drive Module
- System: Rack-mounted System 57 gas detection control system
- Function: Sensor power supply, signal conditioning, gas reading display, alarm comparison, fault supervision and channel status indication
- Configuration: Microprocessor controlled, setup stored in EEPROM
- Optional module: Analogue Output Module 05701-A-0285, isolated 0 to 20 mA or 4 to 20 mA loop
- Related version: 05701-A-0301 is the 4 to 20 mA control card; this 0302 version is for catalytic LEL sensors
- Installation: System 57 rack backplane slot, secured with card retaining screws
Key Specifications
- DC supply: 18 to 32 VDC
- Power consumption: 3.75 W typical, including catalytic sensor
- Sensor type: Catalytic combustible LEL bridge sensor, bridge drive at 200 mA
- Display: 25-segment analog bar, four-character digital reading, four-character message display, power and card select icons
- Alarm LEDs: A1, A2, A3 red gas alarm LEDs; Fault and Inhibit amber LEDs
- Front push-button: Alarm reset and card select
- Alarm setpoint resolution: 1% fsd steps
- Linearity: ±1% fsd
- Repeatability: ±1% fsd
- Electronic drift: Less than ±2% over 6 months
- Remote inputs: RESET and INHIBIT, each configurable active high or active low
- Remote input switching level: Approx. +2 V relative to system 0 V
- Remote input drive current: Less than 5 mA
- Remote input maximum voltage: 32 V
- Optional analogue output: Isolated current loop, 0 to 20 mA or 4 to 20 mA, loop voltage up to 40 V
- Relay outputs: Provided by separate Field Interface or Relay Cards; contact rating 5 A at 110/250 VAC non-inductive, 5 A at 32 VDC non-inductive
- Field terminal cross section: Up to 2.5 mm², 14 AWG
- Card dimensions: Height 112 mm, width 25 mm, depth 170 mm
- Card weight: Approx. 165 g, supplier data
- Operating temperature: -5 to +55 °C
- Storage temperature: -25 to +55 °C
- Humidity: 0 to 90% RH, non-condensing
- EMC: EN50270 per System 57 product data
Features and Advantages
- Dedicated channel control for one catalytic combustible gas detector with matched bridge drive and signal conditioning
- Front analog bar and digital message display show live reading and channel status at a glance
- Three configurable A1, A2 and A3 alarm levels support staged warning and alarm strategies
- Fault supervision detects sensor hardware failure, out-of-limits signal, card hardware or software fault
- Inhibit mode can be applied locally, remotely or automatically during start-up and engineering functions
- EEPROM retains channel configuration, alarm setpoints and calibration data after power loss
- Self-validation checks circuit components, software operation and backplane communications
- Optional isolated analogue output transmits the live reading to recorders, PLCs or remote monitoring systems
- Remote reset and inhibit inputs integrate the channel into plant safety and maintenance procedures
- Card-based rack design allows channel replacement and system expansion within the System 57 cabinet
- Sensor drive module and control card are matched at factory for catalytic sensor compatibility
- Clear LED and message diagnostics speed up commissioning, calibration and troubleshooting
Typical Applications
- Combustible LEL gas detection in oil and gas processing plants
- Chemical and petrochemical storage, pumping and processing areas
- Refineries, tank farms and compressor stations
- Painting, coating and solvent vapor areas
- Power generation, turbine rooms and fuel storage zones
- Industrial boiler rooms, heating plant and combustion equipment monitoring
- System 57 fixed gas detection panels requiring catalytic sensor channel control
- Hazardous area plant monitoring with sensors in the field and control cards mounted in the cabinet
Precautions and Notes
- Confirm the card matches the sensor type: 05701-A-0302 is for catalytic sensors; use 05701-A-0301 for 4 to 20 mA transmitters
- This card controls one detection channel; it does not replace the rack Engineering Card, power supply card or master alarm relay card
- The card mounts in a System 57 rack and requires the correct backplane, DC input card, field interface or relay card arrangement
- Do not apply more than 32 V to remote inhibit or reset inputs; overvoltage can permanently damage the card
- Do not connect the optional analogue output to a loop voltage above 40 V
- Verify relay card type and contact rating before switching mains or inductive loads; AC relay supplies should be fused at max. 5 A
- Alarm relay energisation mode, normally energised or normally de-energised, must be checked in the configuration sheet or engineering software
- Fault relay is permanently configured for energised operation in the non-fault state; alarm relay behavior is configurable
- Remote active low inputs must not be left unconnected; follow active high or active low wiring rules in the manual
- Keep sensor cable screen and armouring correctly earthed; where the sensor is locally earthed, connect the screen at one end only to avoid earth loops
- Configure alarm thresholds, rising or falling action, analog output range and channel labels through the Engineering Card or engineering interface
- Perform zero, span, calibration and alarm test procedures according to the System 57 manual and sensor service schedule
- Maintain the rated -5 to +55 °C operating range and avoid condensation; storage range is -25 to +55 °C
- Remove power before inserting or removing cards to protect the backplane and electronics
- Calibration gas, sensor type and gas range must match the channel configuration and detector rating
- Weight and service conditions are supplier data where not shown on the official manual; confirm against the delivered card label
- For new systems, verify current Honeywell Analytics gas detection controller and detector compatibility before selection