banner
Home PEPPERL+FUCHS

Pepperl+Fuchs KHA6-SH-Ex1 Switch Amplifier

Pepperl+Fuchs KHA6-SH-Ex1 Switch Amplifier

Pepperl+Fuchs KHA6-SH-Ex1 Switch Amplifier

  • Item NO.:

    KHA6-SH-Ex1
  • Payment:

    T/T
  • Price:

    $295
  • Product Origin:

    CHINA
  • Color:

    NEW
  • Product weight:

    0.02KG
  • Lead Time:

    In stock

We will arrange delivery within 3-5 days after receiving the payment.

Our express delivery: DHL and FedEx.

Quality packing for each product

Destination country all taxes & duty to be paid by buyer

Only part of the brand and model, if you have other product needs, please contact us.

                                                                                          • Pepperl+Fuchs KHA6-SH-Ex1 — Switch Amplifier

                                                                                            A 1-channel intrinsically safe isolated barrier from the Pepperl+Fuchs K-System family, used to transfer digital signals from SN/S1N NAMUR proximity sensors or approved dry contacts in hazardous areas to the safe area, while providing galvanic isolation and line fault monitoring.


                                                                                            Key Technical Specifications

                                                                                            表格

                                                                                            Item Specification
                                                                                            Signal type Digital Input
                                                                                            Safety rating SIL 3 (IEC 61508); PL d (EN/ISO 13849)
                                                                                            Supply voltage 85 … 253 V AC, 45 … 65 Hz (auto-range)
                                                                                            Rated current 30 mA ± 5 mA
                                                                                            Power dissipation 2.2 W (≤ 2.3 W)
                                                                                            Input (field side) Terminals 10+/12−; open-circuit voltage ≈ 8.4 V DC; short-circuit current ≈ 11.7 mA
                                                                                            Switching thresholds Relay off: I < 2.1 mA or I > 5.9 mA; Relay on: 2.8 mA < I < 5.3 mA
                                                                                            Response delay ≤ 1 ms
                                                                                            Output I (safety) Relay, 3× form A NO contacts; 253 V AC / 1 A (cos φ ≥ 0.7); 24 V DC / 1 A resistive
                                                                                            Output II Relay, 1× form A NO contact; same contact rating
                                                                                            Output III Passive transistor fault output, 10 … 30 V DC, short-circuit proof
                                                                                            Switching frequency 5 Hz
                                                                                            Mechanical contact life 50 × 10⁶ operations
                                                                                            Galvanic isolation 375 V peak (input/output, input/power supply), per IEC/EN 60079-11
                                                                                            Ex protection [EEx ia] IIC; ATEX cert. PTB 00 ATEX 2043; suitable for Zone 0/1/2
                                                                                            Ambient temperature −20 … +60 °C
                                                                                            Degree of protection IP20
                                                                                            Mounting 35 mm DIN rail (EN 60715)
                                                                                            Dimensions 40 × 93 × 115 mm (housing type E)
                                                                                            Weight ≈ 280 g

                                                                                            Advantages & Features

                                                                                            • High functional safety — certified up to SIL 3 / PL d, suitable for demanding safety-critical loops.
                                                                                            • Universal AC supply — 85–253 V AC wide-range input, no separate 24 V DC supply needed.
                                                                                            • Flexible sensor interface — accepts both NAMUR (SN/S1N) proximity sensors and potential-free dry contacts.
                                                                                            • Three independent outputs — two relay signal outputs (Output I must be used for SIL 3 single-channel safety) plus a dedicated transistor fault indicator.
                                                                                            • Built-in line fault detection (LFD) — continuously monitors lead breakage (LB) and short circuit (SC) on the field circuit.
                                                                                            • Galvanic isolation — safe separation up to 375 V peak between field, control, and supply sides.
                                                                                            • Intrinsic safety — approved for connection to IIC circuits in hazardous Zone 0/1/2.
                                                                                            • LED status indication and compact DIN-rail housing type E for easy panel mounting.

                                                                                            Typical Applications

                                                                                            • Process automation in oil & gas, chemical, petrochemical, and pharmaceutical plants
                                                                                            • Hazardous-area signal transmission (Zone 0/1/2, gas groups IIC)
                                                                                            • Interfacing NAMUR proximity sensors and mechanical safety contacts to PLC/DCS/safety systems
                                                                                            • Emergency shutdown (ESD), burner management, and gas/dust detection loops
                                                                                            • Machinery safety circuits meeting EN/ISO 13849 PL d
                                                                                            • Refineries, offshore platforms, tank farms, and industrial furnace equipment

                                                                                            Notes / Considerations

                                                                                            • Output I (terminals 13/14) must be used to achieve single-channel SIL 3 safety; Output II alone is not sufficient for that rating.
                                                                                            • When connecting mechanical dry contacts, fit a 10 kΩ resistor across the contact and a 1.5 kΩ resistor in series for proper LFD detection.
                                                                                            • Maximum safe voltage Um = 253 V AC/DC is not the rated operating voltage — observe the actual supply range.
                                                                                            • Field cable capacitance and inductance must be kept within Ex ia limits for IIC circuits.
                                                                                            • Lead resistance on the field side must not exceed 50 Ω.
                                                                                            • Observe the ATEX certificate (PTB 00 ATEX 2043), instruction manual, and control drawings during installation and commissioning.
                                                                                            • The device is IP20 — install inside a closed control cabinet; do not expose to conductive dust or moisture.

The structure and details of the product:

 


Please make an inquiry for more models

AUTOMATION DIRECT Appleton GRC50-A

AutomationDirect EA3-S3ML-R

Automation Direct F2-16TD2P

Automation Direct  F2-08AD-1

AutomationDirect EA7-S6M

AUTOMATION DIRECT C0-08TR

Automation Direct MTR2-P33-3BD18 

Automation Direct DVD-2AC4A-120A

Automation Direct    MS25-160 

Automation Direct DN-QG12-2-2 

Automation Direct 11TDT1W4S

AUTOMATION DIRECT   C0-08TR

AUTOMATION DIRECT  DL260

Automation Direct F0-04RTD 

Automation Direct STP-MTRH-34127 

Automation Direct  F0-04RTD

Automation Direct   P3-06DAS-1  

 Automation Direct    P3-08B      

 Automation Direct    P3-11B     

 Automation Direct    P3-16TD1    

 Automation Direct    P3-FILL    

 Automation Direct   ZL-CBL40-2    

 Automation Direct    ZL-P3-CBL20-2   

 Automation Direct    ZL-RTB40-1   

 Automation Direct    EA9-T15CL    

Automation Direct   D2-260 

AUTOMATION DIRECT   EA9-T15CL-R

AUTOMATION DIRECT EA9-7CL 

AUTOMATION DIRECT   P3-550E    

AUTOMATION DIRECT   D2-BAT-1 

AUTOMATION DIRECT   P3-EX 

AUTOMATION DIRECT   P3-SCM   

AUTOMATION DIRECT   P3-16AD-1   

 AUTOMATION DIRECT   P3-RTB   

AUTOMATION DIRECT    P3-16DA-1   

AUTOMATION DIRECT   P3-64ND3    

Automation Direct ZL-RTB40-1

Automation Direct ZL-CBL40-2

Automation Direct P3-16TD1

Automation Direct P3-11B

Automation Direct P3-08B

Automation Direct P3-16AD-1

Automation Direct P3-RTB

Automation Direct P3-16DA-1

Automation Direct P3-64ND3

AUTOMATION DIRECT    F4-16AD-1 

AUTOMATION DIRECT    D4-64TD1

AUTOMATION DIRECT    D4-64ND2

Automation Direct    EZ-220 EZA

AutomationDirect     D0-06DR-D

Automation Direct   P3-16AD1GE

Automation Direct D2-04B-1

Automation Direct F2-16TD2P

Automation Direct P3-SCM 

Automation Direct EA9-T15CL  

 

Automation Direct P3-550

 

Other best-selling products:

  1.  
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related products

KG30-R/EX-2S
PEPPERL+FUCHS KG30-R/EX-2S Safety Control System

PEPPERL+FUCHS KG30-R/EX-2S Safety Control System  

Details
KFU8-UFC-1.D
PEPPERL+FUCHS KFU8-UFC-1.D Inverter with trip value

PEPPERL+FUCHS KFU8-UFC-1.D Inverter with trip value

Details
RL23-8-H-500-RT/47/92 (419472)
PEPPERL+FUCHS RL23-8-H-500-RT/47/92 (419472) Background Suppression Sensor

PEPPERL+FUCHS RL23-8-H-500-RT/47/92 (419472) Background Suppression Sensor

Details
HiC2081
Pepperl+Fuchs HiC2081 Isolated Barrier

Pepperl+Fuchs HiC2081 Isolated Barrier

Details
HiC2025
Pepperl+Fuchs HiC2025 Isolated Barrier

Pepperl+Fuchs HiC2025 Isolated Barrier

Details
VBG-ENX-K20-DMD
Pepperl+Fuchs VBG-ENX-K20-DMD AS-Interface Gateway

Pepperl+Fuchs VBG-ENX-K20-DMD AS-Interface Gateway

Details
SM23165D
MOOG SM23165D Servo Valve

MOOG SM23165D Servo Valve

Details
cMT2166X
Weintek cMT2166X HMI Touch Panel

Weintek cMT2166X HMI Touch Panel

Details

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit
Contact Us:justwellautomation@qq.com

Home

Products

whatsApp

contact