The Honeywell TC810R1024 is an intelligent addressable relay module designed for use with compatible Honeywell fire alarm control panels. It receives commands through the Signaling Line Circuit (SLC) and operates its internal relays to control external devices.
It is commonly used for fire alarm-related automation, including fan shutdown, damper control, door holder release, and resetting four-wire smoke detectors.
|
Parameter |
Description |
|---|---|
|
Brand |
Honeywell |
|
Model |
TC810R1024 |
|
Product Type |
Addressable Relay Module |
|
Product Series |
FlashScan |
|
Communication |
Two-wire SLC |
|
Operating Voltage |
24 VDC |
|
Operating Current |
Approx. 6.5 mA |
|
Relay Outputs |
2 Form-C dry contacts |
|
Relay Operation |
Both contacts switch together |
|
Address Setting |
Dual rotary switches |
|
Address Range |
01–159 (FlashScan); 01–99 (CLIP) |
|
Mounting |
Compatible fire alarm module mounting arrangement |
Addressable Communication: Communicates with compatible Honeywell fire alarm control panels through the SLC loop.
Two Form-C Relay Contacts: Provides dry-contact outputs for controlling external equipment.
Flexible Control: Supports programmed activation through the fire alarm control panel.
Built-in Identification: Automatically identifies itself to the control panel.
Rotary Address Selection: Allows convenient device addressing.
LED Status Indication: Provides visual communication status indication.
HVAC fan and air handling unit shutdown
Fire and smoke damper control
Door holder release systems
Four-wire smoke detector power reset
Auxiliary fire alarm equipment control
Building fire protection systems
Verify compatibility with the installed Honeywell fire alarm control panel.
Set the correct address before commissioning.
Follow the manufacturer's SLC wiring and installation instructions.
Confirm relay contact ratings before connecting external loads.
Installation and testing should be performed by qualified fire alarm technicians.
Reliable addressable relay control
Two dry-contact outputs for auxiliary equipment
Suitable for integration into Honeywell FlashScan fire alarm systems
Supports multiple fire protection and building automation applications