HONEYWELL FC-TSHART-1620M Field Termination Assembly Module
Item NO.:
FC-TSHART-1620MPayment:
T/TPrice:
$800Product Origin:
USAColor:
NEWProduct weight:
0.35kgLead Time:
In stockWe will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us.
HONEYWELL FC-TSHART-1620M Field Termination Assembly Module
The HONEYWELL FC-TSHART-1620M is a field termination assembly module designed for industrial automation and safety systems, particularly in oil & gas, chemical processing, and power generation. It serves as an interface between field devices (e.g., sensors, transmitters) and HART-compatible control systems, ensuring signal integrity and isolation in hazardous environments .
HART Protocol Support: Enables bidirectional digital communication with smart field devices while maintaining 4–20mA analog signals .
16-Channel Isolation: Provides electrical isolation between field and control systems for safety and noise immunity .
Compact Design: DIN-rail mountable for easy integration into control cabinets .
Compatibility: Works with Honeywell Experion PKS and Safety Manager systems .
Parameter | Details |
---|---|
Input Channels | 16× analog (4–20mA with HART) |
Isolation | 1000V AC (field-to-system) |
Protocol | HART 7.x |
Power Supply | 24V DC (via backplane) |
Operating Temp. | -40°C to +70°C |
Certifications | SIL 3 (IEC 61508), ATEX/IECEx for hazardous areas . |
Process Safety Systems: Integrates with Honeywell Safety Manager (FSC) for emergency shutdown (ESD) .
Smart Instrumentation: Connects HART-enabled transmitters (e.g., pressure, temperature) to DCS/PLC systems .
Oil & Gas: Used in refineries and offshore platforms for critical signal conditioning .
Works with:
FC-TSAI-1620M (analog input module) for signal conversion .
Experion PKS C200/C300 controllers .
Installation:
Requires shielded twisted-pair cables for HART communication .
Configured via Honeywell Experion PKS software .
The structure and details of the product:
Please make an inquiry for more models
Honeywell H7080B3273
Honeywell 808630.1
Honeywell CSNS300M-500
Honeywell FS24XP-ANGXX
Honeywell CSNS300M-002S
Honeywell RA890G1260/U
Honeywell 50119638-001
Honeywell ST800 HNS50049911-001
Honeywell TK-FTEB01 51309512-175
Honeywell CSNX25
Honeywell EX-AR20
Honeywell MPD-UTCB1
Honeywell 6PA5-EX
Honeywell 2MLR-CPUH
Honeywell HNS50049911-001
Honeywell AWM43300V
Honeywell ES06F-1/2A
Honeywell TN3801
Honeywell TA3840C
Honeywell DR45AT-1100-00-000-0-0000
Honeywell FC-SCNT01
Honeywell DC300K-E-0A0-10-0000-0
Honeywell 2106B2310
Honeywell 2108B2101H
Honeywell XFL522
Honeywell V5011R1034
Honeywell EC7850A1080
Honeywell DKW972-N
Honeywell C6045D1043
Honeywell A4021A1002
Honeywell LSQ051
Honeywell 2108B2003H
Honeywell DC330B-C00-000-30-000000-00-0
Honeywell UDC-3300
Honeywell SPXCDULNTXF
Honeywell UDC2500 DC2500-CE-0A00-200-00000-00-0
Honeywell 11002000
Honeywell 1NT1-3D
Honeywell CC-TAOX11 51308353-175
Honeywell r404a
Honeywell LSZ51B
Honeywell MU-PLAM02 51304362-150
Honeywell GSAC01A1B
Honeywell 2104B2131 RX MID
Honeywell VRS 3010S20
Honeywell MS4609F1210
Honeywell LS2A4L
Honeywell L6188A2036
Honeywell 8C-PAONAI
Honeywell 190971E
Honeywell STG974
Honeywell 2110B3707
Honeywell 1020-CL 311000
Honeywell MS4604F1210
Honeywell MS4620F1203
Honeywell BZE7-2RN-PG
Honeywell 51305482-105
Honeywell 900PSM-0200
Honeywell 802371
Honeywell 805590
Honeywell evoQ4
Honeywell 900S75S-0460
Honeywell R4343-E1014
Honeywell MPD-AMCB
Honeywell XLS3000
Honeywell 008-1161-000
Honeywell MU-PLAM02 51304362-100
Honeywell EXD-Q-3
Honeywell 900P02-0201
Honeywell BXA3K-1A1
Honeywell UDC3200-CE-100R-200-00000
Honeywell DC2800-CE-0S0-200-000-00-0
Honeywell 51309153-275
Honeywell STT25S-0-ENE-T00-S00-0D0-3D
Honeywell STD820-E1AS4AS-1-C-CHE-11C-B-30A6-F1+0000
Honeywell TH5220D1003
Honeywell SDO-0824
Honeywell 10216/2/1
Honeywell 2MLF-DC8A
Other best-selling products:
--------------占位---------------