Email Us justwellautomation@qq.com
GE Fanuc IC695RMX128-AB Redundant Memory Xchange
Item NO.:
IC695RMX128-ABPayment:
T/TPrice:
$1000Product Origin:
USAColor:
NEWProduct weight:
0.21KGLead Time:
in stockWe will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us.
GE Fanuc IC695RMX128-AB Redundant Memory Xchange Module
The PACSystems* Redundancy Memory Xchange (RMX) module operates as a node on a reflective memory network or as a dedicated link between CPUs in an RX3i Hot Standby CPU Redundancy system. When the RMX is not being used as a link in a redundancy system, it is functionally identical to the IC695CMX128 module. Each node in the network can be any reflective memory device that is compatible with the 5565 family. Whenever data is written to one node, all nodes on the network are automatically updated with the new data.
When used as a node on a reflective memory network, the RMX module provides deterministic sharing of data among PLCs and other computing devices on a high-speed fiber-optic network. A reflective memory network can contain up to 256 nodes.
Each node in the reflective memory network is connected in a daisy chained loop using fiber-optic cables. The transmitter of the first node is tied to the receiver of the second. The transmitter of the second node is tied to the receiver of the third node, and so on, until the loop is completed at the receiver of the first node.
When used in a CPU redundancy system, the RMX modules provide a path for transferring data between the two redundancy CPUs in the redundant system. A complete communications path consists of one RMX in the primary unit, one RMX in the secondary unit, and two high speed fiber-optic cables connecting them to each other. This must be a two-node ring: no other reflective memory nodes are allowed to be part of this fiber-optic network.
GE Intelligent Platforms strongly recommends two redundancy links (a total of four RMX modules) be configured and installed. Optionally, systems can be configured for a single redundancy link (a total of two RMX modules).
When the RMX is being used as link in a redundancy system, it cannot be used as a general-purpose Memory Xchange module. For details on the operation of a PACSystems CPU redundancy system, refer to GFK-2308, PACSystems Hot Standby CPU Redundancy User’s Manual.
A PACSystems RX3i main rack supports a maximum of six Memory Xchange modules in any combination of RMX128, CMX128, and RMX228 modules. A maximum of two RMX modules can be configured as redundancy communication links.
The structure and details of the product:
Please make an inquiry for more models
GE 12CFVB11B1A
GE 12CHC11A21A
GE 12CHC12A28A
GE 12CHC21A2A
GE 12GCX51A11A
GE 12GCX51B13A
GE 12HEA61A224X2
GE 12HFA151A9H
GE 12HFA154E22F
GE 12IAC53B104A
GE 12IAC66K58A
GE 12IAC77B811A
GE 12IAV53L1A
GE 12IAV70B1A
GE 12ICW51A2A
GE 12ICW53A1A
GE 12IJD52A11A
GE 12IJD53C14A
GE 12IJF51A2A
GE 12-inch44A719977-107
GE 12NAA27AC1A
GE 12NLR11E2A
GE 12NLR21B2A
GE 12NLR21E2A
GE 12NLR21M1A
Other best-selling products:
--------------占位---------------