Schneider Electric A9V11463 — Acti9 Vigi iC60 Earth-Leakage Add-On Block
Specifications
表格
| Item |
Details |
| Order code |
A9V11463 |
| Product family |
Acti9 Vigi iC60 |
| Product type |
Vigi earth-leakage add-on block |
| Poles |
4P |
| Rated current In |
63 A |
| Residual current sensitivity |
30 mA |
| Trip delay |
Instantaneous |
| Residual-current class |
Type AC |
| Network type |
AC, 50/60 Hz |
| Rated operational voltage Ue |
400 … 415 V AC |
| Insulation voltage Ui |
500 V AC |
| Impulse withstand Uimp |
6 kV |
| Trip technology |
Voltage-independent residual-current detection |
| Compatible breakers |
Acti9 iC60, Reflex iC60 |
| Mounting |
DIN rail clip-on, screw connection to MCB |
| Modules |
7 × 9 mm width |
| Dimensions W × H × D |
135 × 91 × 73.5 mm |
| Net weight |
Approx. 0.245 kg |
| Terminals |
Tunnel terminal; 1 … 35 mm² solid, 1 … 25 mm² flexible, 1 … 25 mm² ferrule |
| Tightening torque |
3.5 N·m |
| Protection rating |
IP20 |
| Pollution degree |
3 |
| Operating temperature |
-5 … +60 °C |
| Storage temperature |
-40 … +85 °C |
| Standards |
EN/IEC 61009-1, EN/IEC 61009-2-1 |
| Local indication |
VisiTrip red mechanical trip indicator |
Features and Advantages
- Adds 30 mA residual-current protection to a compatible iC60 MCB for electric-shock and earth-fault protection.
- Type AC detection responds to sinusoidal residual leakage currents in standard AC installations.
- Voltage-independent trip technology maintains residual-current protection even under control-voltage loss conditions.
- 4P configuration suits three-phase four-wire 400/415 V distribution boards.
- Red VisiTrip indicator gives clear visual confirmation after a trip event.
- Unified terminal design and wiring indication simplify assembly and maintenance.
- DIN rail mounting and screw connection to the MCB support standard Acti9 panel construction.
- Filtering design helps reduce nuisance tripping from transient leakage currents.
Applications
- Three-phase distribution boards in commercial and industrial buildings
- Socket circuits, machine feeds and three-phase load earth-fault protection
- Addition of residual-current protection to existing iC60 breaker arrangements
- Protection against indirect contact, insulation faults and fire risk from leakage currents
- Acti9 panel upgrades where an integrated Vigi function is required
Installation and Usage Notes
- The block does not provide overload or short-circuit protection; pair it with the correct compatible iC60/Reflex iC60 MCB.
- Verify the MCB current rating, breaking capacity and pole arrangement match the load and installation fault level.
- Type AC is for conventional AC circuits; do not use it where Type A, B or SI protection is required by the local wiring standard.
- Check conductor cross-section, cable stripping length and 3.5 N·m terminal torque before energizing.
- Maintain correct phase and neutral connection; confirm neutral position according to the device marking.
- Perform the RCD test after installation and periodically afterward using an earth-leakage tester.
- Avoid installing in damp, corrosive or contaminated locations beyond the stated IP20 and environmental ratings.
- Confirm regional certification and wiring-code compliance before use.