We will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us.
The ABB SACO16D1 is a compact, industrial-grade digital annunciator unit designed for real-time monitoring and alerting of process faults or status changes in industrial automation systems (e.g., DCS, PLC-based control systems). It collects discrete input signals from field devices (sensors, switches, controllers) and visually/audibly notifies operators of abnormal conditions (e.g., high temperature, low pressure, equipment failure) via LED indicators and an audible alarm. Engineered for high reliability, easy configuration, and compatibility with diverse industrial protocols, it serves as a critical human-machine interface (HMI) component to enhance situational awareness and enable fast fault response in mission-critical processes. Below is its detailed specification:
- Product Model: SACO16D1
- Product Type: Digital annunciator unit (16-channel, discrete input monitoring)
- Core Function: Monitors 16 discrete input signals; triggers visual (LED) and audible alarms for abnormal conditions; supports alarm acknowledgment and reset
- Input Specifications:
- Number of Input Channels: 16 (isolated discrete inputs)
- Input Type: Dry contact (NO/NC) or voltage input (24V DC, 110V AC/DC, 230V AC; selectable via DIP switch)
- Input Isolation: 2.5kVrms (between each input channel and ground; prevents cross-talk)
- Input Response Time: ≤10ms (from signal change to alarm activation)
- Input Resistance: ≥100kΩ (for voltage inputs); ≤1Ω (for dry contact inputs)
- Alarm & Indication Features:
- Visual Indication: 16 individual LEDs (per channel) with 3 color states—
- Green: Normal (input signal in safe range)
- Red: Alarm (input signal indicates abnormal condition)
- Amber: Acknowledged alarm (alarm detected, operator acknowledged but not resolved)
- Audible Alarm: Built-in piezoelectric buzzer (85dB @ 1m; adjustable volume: 60~90dB)
- Alarm Acknowledgment: Local pushbutton (ACK) or remote signal input (via PLC/DCS)
- Alarm Reset: Local pushbutton (RESET) or remote signal input; resets resolved alarms to normal state
- Communication & Configuration:
- Communication Protocol: Modbus-RTU (RS-485 interface; baud rate: 9600~115200 bps, parity: None/Even/Odd)
- Configuration: Via front-panel DIP switches (input type, voltage range) or Modbus-RTU (alarm logic, LED behavior)
- Alarm Logic: Selectable (NO: alarm on contact open; NC: alarm on contact close) per channel
- Power Supply:
- Input Voltage: 24V DC (±15% tolerance) or 110/230V AC (±10% tolerance; selectable via DIP switch)
- Power Consumption: ≤15W (at 24V DC, full load); ≤20W (at 230V AC, full load)
- Mechanical Specifications:
- Housing Type: Panel-mounted (IP40 front; IP20 rear; suitable for control room cabinets)
- Dimensions (W×H×D): 144mm × 144mm × 80mm (standard 6-inch square panel cutout)
- Mounting: Flush panel mounting (panel thickness: 1~5mm)
- Weight: Approximately 450g
- Environmental Ratings:
- Operating Temperature Range: 0℃~+55℃ (32℉~131℉)
- Storage Temperature Range: -20℃~+70℃ (-4℉~158℉)
- Humidity Tolerance: ≤90% RH (non-condensing, 40℃)
- Vibration Resistance: 10~500Hz, 1g acceleration (IEC 60068-2-6; no false alarms)
- Shock Resistance: 20g acceleration (11ms duration, IEC 60068-2-27; maintains functionality)
- Compliance Standards: IEC 61508 (functional safety, SIL 1), IEC 61000-6-2 (EMC immunity), UL 508 (industrial control safety), CE
- 16-Channel Monitoring Capacity: Supports up to 16 discrete inputs, enabling centralized monitoring of multiple process points (e.g., 8 temperature sensors + 8 pressure switches) in a single compact unit—reducing panel space and installation costs.
- Dual Alarm Indication: Combines bright, color-coded LEDs (per channel) and an adjustable-volume audible buzzer to ensure operators quickly detect alarms, even in noisy control rooms or low-light environments.
- Flexible Input Compatibility: Accepts both dry contacts (for mechanical switches) and voltage inputs (for electronic sensors), with selectable voltage ranges (24V DC~230V AC)—compatible with diverse field devices and legacy systems.
- Local & Remote Control: Enables alarm acknowledgment/reset via front-panel buttons (for on-site operators) or remote signals (via Modbus-RTU from PLC/DCS)—supports both manual and automated alarm management workflows.
- Modbus-RTU Integration: Seamlessly connects to upper-level systems (SCADA, DCS, PLCs) via Modbus-RTU, allowing remote configuration (e.g., adjusting alarm logic) and data logging (e.g., alarm timestamps, channel status)—enhancing system visibility and traceability.
- Isolated Input Channels: 2.5kVrms isolation between channels prevents signal cross-talk and protects the unit from voltage surges (e.g., from faulty field sensors)—ensuring reliable operation and reducing downtime.
- Industrial-Grade Durability: IP40 front protection, wide temperature range, and vibration resistance make it suitable for harsh industrial environments (e.g., chemical plants, power stations) while maintaining consistent performance.
- Process Industry (Chemical/Petrochemical): Monitors safety interlocks (e.g., reactor high-pressure switches, fuel gas leak detectors) and process status (e.g., valve position, pump running state)—alerting operators to critical faults to prevent accidents or process shutdowns.
- Power Generation: Tracks auxiliary system status in thermal, nuclear, or renewable energy plants (e.g., boiler water level, turbine bearing temperature, solar inverter faults)—enabling fast response to maintain grid stability.
- Water & Wastewater Treatment: Monitors pump running status, filter pressure differentials, and chemical dosing levels—alerting operators to issues like clogged filters or pump failures that could violate environmental regulations.
- Manufacturing Automation: Centralizes monitoring of production line sensors (e.g., conveyor jam detectors, robotic arm position switches, quality inspection triggers)—reducing downtime by quickly identifying bottlenecks or equipment malfunctions.
- Oil & Gas (Midstream/Downstream): Monitors pipeline pressure, storage tank level, and refinery unit status (e.g., distillation column temperature)—ensuring safe, efficient operation of midstream infrastructure and downstream processing.
- Food & Beverage Production: Tracks critical process parameters (e.g., pasteurization temperature, filling machine pressure, cold storage door status)—alerting operators to deviations that could compromise product quality or food safety (e.g., FDA compliance).
- Input Type Configuration: Ensure DIP switches are set correctly for input type (dry contact/voltage) and voltage range before powering on. Incorrect settings (e.g., voltage input mode with dry contact wiring) will damage the unit or cause false alarms.
- Isolation Wiring: Maintain proper isolation between input channels and ground. Do not share ground wires between channels—this can bypass isolation and cause cross-talk or equipment damage.
- Audible Alarm Setup: Adjust the buzzer volume to a level that is audible but not disruptive (typically 70~80dB in control rooms). Mute the buzzer only temporarily (e.g., during maintenance) to avoid missing critical alarms.
- Modbus-RTU Configuration: Verify Modbus parameters (baud rate, parity, slave address) match those of the upper-level system (PLC/DCS). Mismatched parameters will prevent communication, disabling remote control and data logging.
- Environmental Protection: Install the unit in a closed control panel to shield from dust, moisture, and direct sunlight. Avoid mounting near heat sources (e.g., power supplies, motor drives) or in areas with temperatures exceeding +55℃.
- Maintenance Checks: Inspect quarterly:
- Test each input channel by simulating a fault (e.g., opening a dry contact) to confirm LED and buzzer activation.
- Verify Modbus communication by checking remote status updates in the upper-level system.
- Clean the front panel (with a dry cloth) to ensure LED visibility and button functionality.
- Alarm Management: Establish clear protocols for alarm acknowledgment/reset (e.g., require two operators to reset critical alarms). Do not ignore acknowledged alarms—resolve the root cause promptly to prevent recurring issues



The structure and details of the product:

Please make an inquiry for more models
ABB HIEE401091R0002 GD9924BE
ABB HIEE401481R0001 UAC326AE
ABB HIEE450964R0001 SA9923A-E
ABB HIEE451116RW01 FW9925a-E
ABB JANCD-CP01B
ABB JANCD-GI
ABB JANCD-PW02
ABB LDGRB-01
ABB LD800HSE 3BDH000320R02
ABB LDGRB-01 3BSE013177R1
ABB PFBK165 3BSE000470R1
ABB PFSK102 YM322001-EG
ABB PFVI102 YM110001-SN
ABB PM802F 3BDH000002R1
ABB PR221DS-LSI
ABB QHMX325
ABB R6581T
ABB REF615R HBFHAEAGANB1BNN11G
ABB RINT-5521C 3AUA0000016016E
ABB SAFT 121 PAC
ABB SDCS-IOE-1
ABB SDCS-IOE-2C
ABB SINT4611C
ABB SPAD346C3
ABB T1N160 1SDA050929R1
ABB T3N250
ABB T5H400
ABB T5H630
ABB T5N400 R400 TMA
ABB T5N630
ABB T5S630
ABB T6N630
ABB T6N800
ABB T6S800
ABB TA200DU-175 1SAZ421201R1005
ABB TA25DU
ABB TA25DU-11M
ABB TA25DU-14M
ABB TA25DU-19M 8.8
ABB TA25DU-2.4M
ABB TA25DU-5.0
ABB TA25DU-4.0M
ABB TA25DU-4M
ABB TA25DU-5.0M
ABB TA25DU-6.5M 1SAZ211201R2038
ABB TA42DU-42M
ABB TA75DU-52M
ABB TB820V2 3BSE013208R1
ABB OT32E3
ABB cint-01c
ABB RDCO-01С
ABB BC810K02 3BSE031155R1
ABB 07KT97 GJR5253000R0160
ABB 07DC91 GJR5251400R0202
ABB ICSF08D1 FPR3323101R1012
ABB 1TGE120021R0110
ABB UA110-30-11
ABB UNS-0869A-P 3BHB001337R0002
ABB WT98 GJR5253100R4278
ABB XT2H160
ABB XT4H250 1SDA068345R1
ABB XVC768AE102
ABB YXU168E YT204001-JB/1
ABB 07BA60R1
ABB 07BE60R1
ABB 07BE62R1
ABB 07BR60R1
ABB 07BR61R1
ABB 07BT60R1
ABB 07EA64R1
ABB 07EA65R1
ABB 07EA66R1
ABB 07EA67R1
ABB 07EB61R1
ABB 07EI60
ABB 07AA61
Other best-selling products:
--------------占位---------------