We will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us.
ABB 1SDA073687R1 Low-Voltage Air Circuit Breaker
Product Description
Low-voltage air circuit breaker (ACB) for medium-to-large capacity low-voltage distribution systems, specializing in main power inlet protection, heavy load switching, and fault isolation—critical for industrial parks, large factories, and high-power commercial facilities to ensure stable power supply and electrical safety.
Key Specs
- Rated Current (In): 800A (frame size); rated breaking capacity (Icu): 65kA (415V AC, 50Hz).
- Voltage Rating: 415V AC (max operating voltage); 250V DC (auxiliary circuit).
- Protection Functions: Overcurrent (long-time/short-time/instantaneous, adjustable thresholds), earth fault protection (20-5000mA, selective tripping).
- Mechanical Life: ≥10,000 operations; electrical life (rated current): ≥2000 operations.
- Env: -5°C~+40°C, 5%-95% RH (non-condensing), IP30 (enclosed switchboard installation).
- Control & Operation: Manual/electric operating mechanism (remote control optional); compatible with ABB Ekip Hi-T trip units for intelligent monitoring.
Core Advantages
- Higher breaking capacity: 65kA at 415V AC handles severe short-circuit faults in high-capacity distribution systems (e.g., 800A main circuits).
- Precise protection: Adjustable overcurrent/earth fault settings support selective tripping, avoiding large-area power outages.
- High current adaptability: 800A rated current meets heavy load demands (e.g., multiple large motors in factories).
- Intelligent expansion: Ekip Hi-T trip unit compatibility enables real-time data logging, fault analysis, and remote monitoring.
Applications
- Main incoming circuit protection for large manufacturing plants (800A power inlet, 415V low-voltage system).
- Power distribution protection in industrial parks to isolate zone-level faults without affecting other areas.
- High-power commercial facility (e.g., large shopping malls, hotels) main switchboard protection, supporting multiple heavy-load circuits.
Precautions
- Wiring: Main circuit use 150mm² copper cables; torque main terminals to 60-65N·m, auxiliary terminals to 8-10N·m to avoid contact overheating.
- Protection setting: Match long-time overcurrent setting to actual load current (e.g., 800A for full-load operation); set instantaneous current to 12×In for motor-dominated loads.
- Installation: Mount vertically in switchboards; reserve 20cm clearance above/below for heat dissipation and manual operation space.
- Maintenance: Test trip function quarterly (both manual and electric modes); inspect contact surface annually—polish minor oxidation, replace if contact wear exceeds 40% of original thickness.
- Compatibility: Only use ABB-certified trip units (e.g., Ekip Hi-T) and accessories; non-approved parts may cause protection failure or mechanical jamming.
-
-
The structure and details of the product:

Please make an inquiry for more models
ABB TB815
ABB PP815
ABB PP820
ABB PP825
ABB PP826
ABB PP835 3BSE042234R2
ABB PP836
ABB PP845 3BSE042235R1
ABB PP846
ABB PP865
ABB PP871
ABB PP874 6.20
ABB PP877 3BSE069272R2
ABB TK854V030
ABB CB801
ABB CB810
ABB RX835
ABB RX865
ABB 07KP93B
ABB 07KR228
ABB 07KR264dR1
ABB 07KR264b
ABB 07KR220dR1
ABB 07KR220R1
ABB 07KR240R2
ABB 07KR240bR2
ABB 07KR228R2
ABB 07KT51
ABB 07KR51-A
ABB 07KR31
ABB 07KT31
ABB 07KP96
ABB 07KR91
ABB 07KP90
ABB 07KT93
ABB 07KP92
ABB 07KP92E1
ABB 07KP94
ABB 07KP95
ABB 07KT94
ABB DSAI303
ABB DSAI305
ABB DSAO301
ABB DSAV110
ABB DSAV111
ABB DSBB102
ABB DSBB107
ABB DSBB110
ABB DSBB110A
ABB DSBB170
ABB DSBB175
ABB DSBBN001-0
ABB DSBBN002-0
ABB DSBC110
ABB DSBC111
ABB DSBC170
ABB DSBSN001
ABB DSCA114
ABB DSCA124
ABB DSCA125A
ABB DSCA130
ABB DSCA170
ABB DSCA180B
ABB DSCA190V
ABB DSCA310
ABB DSCA325
ABB DSCI112
Other best-selling products:
--------------占位---------------