ABB 1SDA073674R1 Low-Voltage Air Circuit Breaker
Product Description
Low-voltage air circuit breaker (ACB) for low-voltage power distribution systems, designed for main circuit protection, load switching, and fault isolation—core for industrial plants, commercial buildings, and data centers to ensure safe and reliable power supply.
Key Specs
- Rated Current (In): 630A (frame size); rated breaking capacity (Icu): 50kA (415V AC, 50Hz).
- Voltage Rating: 415V AC (max operating voltage); 250V DC (auxiliary circuit).
- Protection Functions: Overcurrent (long-time/short-time/instantaneous), earth fault protection (30-3000mA adjustable).
- Mechanical Life: ≥10,000 operations; electrical life (rated current): ≥2000 operations.
- Env: -5°C~+40°C, 5%-95% RH (non-condensing), IP30 (enclosed installation).
- Control & Operation: Manual/electric operating mechanism; compatible with ABB Ekip trip units (e.g., Ekip LS) for intelligent protection.
Core Advantages
- High breaking capacity: 50kA at 415V AC handles short-circuit faults in medium-capacity distribution systems.
- Comprehensive protection: Multi-stage overcurrent + earth fault protection prevents equipment damage and electrical hazards.
- Flexible operation: Manual/electric control adapts to on-site operation needs (e.g., remote electric switching for data centers).
- Intelligent compatibility: Supports Ekip trip units for real-time current monitoring and fault data recording.
Applications
- Main incoming circuit protection for industrial plant low-voltage switchboards (630A rated current, 415V system).
- Power distribution protection in commercial buildings (e.g., shopping malls) to isolate floor-level power faults.
- Backup circuit protection for data center UPS systems (ensures safe switching during power backup/restore).
Precautions
- Wiring: Main circuit use 120mm² copper cables; torque terminals to 45-50N·m (main contacts) and 8-10N·m (auxiliary contacts).
- Protection setting: Set overcurrent/earth fault thresholds per system design (e.g., instantaneous current = 10×In for motor loads).
- Installation: Mount vertically in switchboards; ensure 15cm clearance above/below for heat dissipation and operation.
- Maintenance: Test trip function quarterly (manual/electric operation); check contact wear annually (replace if contact thickness <50% of original).
- Compatibility: Use ABB-approved trip units and accessories—non-approved parts may affect protection performance.
-
The structure and details of the product:

Please make an inquiry for more models
ABB TB815
ABB PP815
ABB PP820
ABB PP825
ABB PP826
ABB PP835 3BSE042234R2
ABB PP836
ABB PP845 3BSE042235R1
ABB PP846
ABB PP865
ABB PP871
ABB PP874 6.20
ABB PP877 3BSE069272R2
ABB TK854V030
ABB CB801
ABB CB810
ABB RX835
ABB RX865
ABB 07KP93B
ABB 07KR228
ABB 07KR264dR1
ABB 07KR264b
ABB 07KR220dR1
ABB 07KR220R1
ABB 07KR240R2
ABB 07KR240bR2
ABB 07KR228R2
ABB 07KT51
ABB 07KR51-A
ABB 07KR31
ABB 07KT31
ABB 07KP96
ABB 07KR91
ABB 07KP90
ABB 07KT93
ABB 07KP92
ABB 07KP92E1
ABB 07KP94
ABB 07KP95
ABB 07KT94
ABB DSAI303
ABB DSAI305
ABB DSAO301
ABB DSAV110
ABB DSAV111
ABB DSBB102
ABB DSBB107
ABB DSBB110
ABB DSBB110A
ABB DSBB170
ABB DSBB175
ABB DSBBN001-0
ABB DSBBN002-0
ABB DSBC110
ABB DSBC111
ABB DSBC170
ABB DSBSN001
ABB DSCA114
ABB DSCA124
ABB DSCA125A
ABB DSCA130
ABB DSCA170
ABB DSCA180B
ABB DSCA190V
ABB DSCA310
ABB DSCA325
ABB DSCI112
Other best-selling products:
--------------占位---------------