Email Us justwellautomation@qq.com
EMERSON KJ3222X1-BA2 DeltaV Analog Output Module
Item NO.:
KJ3222X1-BA2Payment:
T/TPrice:
$730Product Origin:
USAColor:
NEWGoods stock:
4Product weight:
0.08KGLead Time:
in stockWe will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us
Important product identification correction: The Emerson KJ3222X1-BA2 is an Analog Input (AI) Module, not an Analog Output (AO) Module.
It is an 8-channel Series 2 analog input card for the Emerson DeltaV M-series control system. It receives 4–20 mA signals from field transmitters and supports HART communication for accessing smart instrument data and diagnostics.
|
Parameter |
Specification |
|---|---|
|
Brand |
Emerson |
|
Model |
KJ3222X1-BA2 |
|
Product Type |
Analog Input Module |
|
Product Series |
DeltaV M-Series Series 2 |
|
Number of Channels |
8 |
|
Input Signal |
4–20 mA DC |
|
Communication |
HART |
|
HART Function |
Digital communication / pass-through |
|
Resolution |
16-bit |
|
Accuracy |
0.1% of span |
|
LocalBus Power |
12 VDC, 150 mA |
|
Bussed Field Power |
24 VDC, 300 mA |
|
Field Circuit Power |
24 VDC, 30 mA per channel |
|
Operating Temperature |
-40 to +70°C |
|
Relative Humidity |
5–95%, non-condensing |
|
Corrosive Environment Rating |
ISA-S71.04 Class G3 |
8 independent analog input channels.
Supports standard 4–20 mA industrial signals.
HART communication for smart field instrument diagnostics.
16-bit signal resolution.
Designed for DeltaV M-series Series 2 I/O architecture.
Supports integration with compatible DeltaV terminal blocks and carriers.
Suitable for demanding industrial environments.
Pressure transmitter monitoring
Flow measurement
Level measurement
Temperature transmitter monitoring
Oil and gas processing
Chemical and petrochemical plants
Industrial process automation
Confirm compatibility with the DeltaV M-series Series 2 I/O carrier.
Use the appropriate terminal block and verify its keying position.
Check the 4–20 mA loop wiring and HART configuration.
Verify the installed DeltaV software version before replacement.
For hazardous-area installation, follow the applicable field-power isolation and installation requirements.
This module cannot be removed or inserted with system power energized under the applicable installation instructions.
The structure and details of the product:

Please make an inquiry for more models
YOKOGAWA F3PU30-0S
YOKOGAWA F3SP71-4S
YOKOGAWA F3WD64-3P
YOKOGAWA F3XD64-3F
YOKOGAWA F3YD64-1P
YOKOGAWA F3AD04-5V
YOKOGAWA F3DA08-5R
YOKOGAWA F3LC11-2F
YOKOGAWA F3YD32-1P
ABB TU847
ABB AINP-01C
ABB ZMU-02
ABB AX522 1SAP250000R0001
GE SELA36AT0060
SIEMENS 6DP1210-7BA
SIEMENS 3RH2911-2XA40-0MA0
A-B 1762SC-IF8u
Siemens 3VA2463-6HM32-0AA0
Siemens 1XP8001-1
Foxboro C0135YN
Foxboro C0136HZ
Lenze EVF8203-E
B&R 8I74T400037.010-1
Janitza UMG 96 RM-EL