ABB TKMA3Y1200AMP Molded Case Circuit Breaker
Item NO.:
TKMA3Y1200AMPPayment:
T/TPrice:
$200Product Origin:
SwedenColor:
NEWLead Time:
In stockWe will arrange delivery within 3-5 days after receiving the payment.
Our express delivery: DHL and FedEx.
Quality packing for each product
Destination country all taxes & duty to be paid by buyer
Only part of the brand and model, if you have other product needs, please contact us.
The ABB TKMA3Y1200AMP is a Molded Case Circuit Breaker (MCCB) designed for industrial and commercial power distribution systems, providing overload and short-circuit protection. It features high rated current capacity, fast response, and reliable interruption, effectively protecting circuits and equipment. The TKMA series is compact and suitable for industrial and high-power applications.
Model: TKMA3Y1200AMP
Brand: ABB
Type: Molded Case Circuit Breaker (MCCB)
Rated Current: 1200 A
Number of Poles: 3P
Rated Insulation Voltage: 1000 V AC
Rated Operational Voltage: 690 V AC
Short-Circuit Breaking Capacity: up to 65 kA (AC-3, 400 V)
Trip Characteristics: Thermal-magnetic trip, adjustable overload and short-circuit protection
Mechanical Life: ~10,000 operations
Electrical Life: ~5,000 operations (rated load)
Protection Rating: IP20
Mounting: Panel or rack-mounted
Applications: Industrial distribution, plant main distribution, substations, and large motor protection
High Rated Current – 1200 A for large industrial distribution systems.
Overload & Short-Circuit Protection – Thermal-magnetic trip provides fast response to faults.
High Reliability – Quality materials and precise mechanisms ensure long-term stable operation.
Compact Design – Saves installation space compared to similar-rated breakers.
Adjustable Protection – Trip settings can be adjusted according to load requirements.
Standardized & Safe – Compliant with IEC/EN 60947-2 for safe industrial and commercial distribution.
Industrial plant main distribution
Large motor and drive equipment protection
Factory automation and production line power distribution
Substations and distribution rooms
Energy management systems and distribution networks
HVAC systems and large building electrical control
Power Matching – Ensure voltage and current match the breaker’s rated values.
Secure Wiring – Terminals must be tightened to prevent arcing and poor contact.
Environmental Conditions – Avoid moisture, dust, and corrosive gases; ensure proper ventilation.
Operation Guidelines – Avoid frequent manual operation under load; ensure trip functions operate correctly.
Regular Inspection – Check mechanical operation, contact wear, and terminal connections regularly for safe operation.