The ABB REJ601 is a high-performance numerical feeder protection relay designed for the protection, control, and monitoring of medium-voltage (MV) feeders in power distribution networks. As a core component of MV switchgear, it safeguards feeders against electrical faults such as overcurrent, short circuits, earth faults, and overloads—with precise, fast tripping to minimize damage to equipment and reduce power outage duration.
Equipped with advanced numerical technology, the REJ601 supports flexible configuration, real-time data monitoring, and communication with SCADA/DCS systems (via protocols like IEC 61850, Modbus, or DNP3.0). It is widely used in industrial power networks, utility distribution grids, commercial buildings, and infrastructure projects (e.g., airports, railways) to ensure the reliability and safety of MV feeder circuits.
- Utility Distribution Grids: Protects MV feeders (10kV/20kV) in urban or rural power distribution networks, isolating faults (e.g., line-to-ground short circuits) to prevent outages from spreading to other areas.
- Industrial Power Networks: Safeguards MV feeders supplying power to factories (e.g., manufacturing plants, refineries) or industrial parks—ensuring uninterrupted power for critical production lines by quickly clearing overloads or short circuits.
- Commercial & Infrastructure Projects: Used in airports, railways, or large commercial complexes to protect MV feeders powering auxiliary systems (e.g., lighting, HVAC, traction power for trains), minimizing downtime for public services.
- Renewable Energy Integration: Protects MV feeders connecting solar/wind farms to the grid, preventing overcurrent from renewable energy fluctuations (e.g., sudden wind gusts) and ensuring grid stability.
- Comprehensive Protection Coverage: Integrates all essential feeder protection functions (overcurrent, earth fault, overload) in one device, eliminating the need for multiple standalone relays and simplifying system design.
- Fast & Precise Tripping: Inverse-time tripping curves (e.g., IEC standard curves like IDMT, EIDMT) enable selective fault clearing—tripping only the faulty feeder while keeping adjacent circuits operational, reducing outage 范围.
- Advanced Communication: Native IEC 61850 support enables seamless integration with smart grids and digital substation systems, facilitating remote monitoring, configuration, and fault diagnosis (e.g., real-time fault location via SCADA).
- Flexible Configuration: User-defined protection settings (e.g., tripping delays, current thresholds) and optional functions (breaker failure protection) adapt to diverse feeder types (e.g., overhead lines, cables) and network requirements.
- Reliable Operation: Industrial-grade components, wide temperature tolerance (-25°C to +70°C), and robust EMC immunity (IEC 61000-6-2) ensure stable performance in harsh MV switchgear environments (dust, vibration, electrical interference).
- CT/VT Matching: Ensure CT (current transformer) and VT (voltage transformer) ratings match the relay’s input specifications (e.g., 5A CT for 5A input relay). Mismatched CT/VT will cause measurement errors or failed protection.
- Protection Setting Calibration: Configure tripping curves and thresholds based on the feeder’s load characteristics (e.g., use IDMT curve for overhead lines, definite time for cables) and coordinate with upstream/downstream relays to avoid "nuisance tripping" or delayed fault clearing.
- Communication Network Security: For IEC 61850/Modbus TCP, implement network security measures (e.g., firewalls, access control lists) to prevent unauthorized access or cyber threats to the relay.
- Regular Testing: Perform periodic functional tests (e.g., inject test currents to verify tripping, check communication connectivity) and calibration (annually recommended) to ensure protection logic operates correctly.
- Fault Record Analysis: Use the relay’s built-in fault recorder (to capture pre-fault/post-fault data) to analyze fault causes (e.g., short circuit location, overload duration) and optimize network reliability.
- Genuine Spare Parts: Only replace components (e.g., power supply modules, relay outputs) with ABB-approved parts—non-genuine parts may compromise protection performance and void the warranty.

The structure and details of the product:

Please make an inquiry for more models
ABB DSDI110AV1
ABB DSDO115A
ABB DSAI130D
ABB DSBC176
ABB DSAO120A
ABB DSAI146
ABB DSDP150
ABB DSDO115
ABB PM511V08
ABB SC520
ABB SC510
ABB DSTX170
ABB AMC-DC
ABB E234 CT-AHD 3AUA0000032859
ABB 5STP28L4200
ABB UUD148AE01 3BHE014185R0001
ABB TTH200
ABB SB510
ABB SR511
ABB UAC389AE01
ABB LDSYN-101
ABB SDCS-IOE-2 7.7
ABB LDMUI-01
ABB CP502
ABB DSQC633A
ABB NDPC-02
ABB DLM02
ABB 5SHX1960L0004
ABB 5SHY3545L0003
ABB 5SDF1645L0001
ABB FAU810
ABB 3HAA0001-ADX/O
ABB 3HAA0001-BP
ABB 3HAA3563-AAA
ABB 3HAA3563-ARA
ABB 3HAB3700-1
ABB 3HAB8101-8/08Y
ABB 3HAB8278-1
ABB 3HAC025466-001
ABB 3HAC031683-001
ABB 3HAC14550-2/09A
ABB 3HAC14550-4/04B
ABB 3HAC17326-1/02
ABB 3HAC17346-1/01
ABB 3HE01171AA
ABB 3he01473aa01
ABB 3HNA000512-001
ABB 3HNM07686-1
ABB DSQC101
ABB DSQC103
ABB DSQC103 YB161102-AD
ABB YB161102-AD
ABB DSQC105
ABB DSQC107
ABB DSQC115
ABB DSQC116
ABB YB161102-BE
ABB DSQC123B
ABB DSQC129
ABB DSQC129 YB161102-BVS2
ABB DSQC116 YB161102-BE
ABB DSQC142
ABB DSQC200
ABB DSQC202
ABB DSQC208
ABB DSQC208A
ABB DSQC209
ABB DSQC210
Other best-selling products:
--------------占位---------------