ABB REB670 Digital Protection Relay
Product Description
The ABB REB670 is an intelligent electronic device (IED) engineered for the protection and monitoring of bus bars, T - connections, and meshed corners in power systems. It operates across a wide voltage spectrum, from medium to extra - high voltage levels, with the ability to cover up to six zones. As part of ABB's Relion protection and control product family, it adheres to the IEC 61850 standard, enabling seamless integration and interoperability within modern power systems.
Core Protection Functions
- Differential Protection: The REB670 features a highly sensitive differential protection mechanism. It constantly monitors the incoming and outgoing currents at various points in the protected zone. In the event of an internal fault, such as a short - circuit between phases or to earth, the differential current exceeds the set threshold, and the relay quickly initiates tripping. This ensures selective, reliable, and fast fault clearance, minimizing the impact on the power system. For example, in a large industrial substation with complex busbar arrangements, the differential protection of REB670 can accurately identify and isolate faults, preventing widespread power outages.
- Current Protection: Multiple stages of over - current protection are incorporated. These can be set to respond to different levels of abnormal current flow. Instantaneous over - current protection acts rapidly for severe short - circuit faults, while time - graded over - current protection is designed to handle less severe but sustained over - current conditions. This multi - stage approach provides comprehensive protection against a range of current - related issues, such as overloads caused by sudden increases in load demand or faults in connected equipment.
- Zone Selection: With its advanced zone - selection capabilities, the REB670 can precisely determine the location of a fault within the protected areas. This is crucial for complex power system topologies where there are multiple interconnected busbars and feeder lines. By accurately pinpointing the fault zone, the relay can isolate only the affected section, preserving power supply to the rest of the system. For instance, in a power grid with a ring - main unit configuration, the REB670 can quickly identify which part of the ring has a fault and take appropriate action.
Technical Specifications
- Voltage Range: Can be configured to operate in power systems with voltages ranging from medium voltage (e.g., 10 - 35 kV) up to extra - high voltage (e.g., 220 - 500 kV), making it suitable for a wide variety of substation applications.
- Current Inputs: Accepts multiple current inputs, typically with a rated current of 1 A or 5 A. The input current range can be adjusted to suit different system requirements, ensuring accurate current measurement and protection operation.
- Communication Interfaces: Equipped with a range of communication interfaces, including IEC 61850 - 8 - 1 for seamless integration into modern substation automation systems, Modbus for compatibility with legacy systems, and DNP 3 for remote monitoring and control. This allows for easy data exchange with other devices in the substation, such as remote terminal units (RTUs) and control centers.
- Power Supply: Operates on a wide - range power supply, typically 24 - 250 V DC ± 20% or 110 - 230 V AC ± 15%, providing flexibility in installation across different power system setups.
- Mechanical Dimensions: Compact in design, with dimensions optimized for easy installation in standard 19 - inch racks. The physical size allows for efficient use of space in control panels and relay cubicles.
- Protection Class: Features a protection class of IP40 (front) and IP20 (rear), providing protection against solid objects larger than 1.0 mm and dust, ensuring reliable operation in various environmental conditions.
Advantages & Features
- Versatile Busbar Protection: Due to its extensive I/O capabilities, the REB670 can protect single, double, and triple busbars, with or without transfer bus, double - circuit breaker, or one - and - half circuit breaker arrangements. This versatility makes it suitable for a wide range of substation configurations, from simple industrial substations to complex utility - scale power distribution centers.
- High - Speed Operation: The relay is designed for fast operation, with typical tripping times in the order of milliseconds. In the case of a fault, this rapid response helps to minimize damage to equipment and reduce the duration of power outages, enhancing the overall reliability of the power system.
- Advanced Monitoring and Diagnostic Features: Equipped with an integrated disturbance recorder, the REB670 can capture and store detailed information about electrical disturbances, such as voltage and current waveforms during a fault. This data is invaluable for post - fault analysis, helping engineers to quickly identify the root cause of the problem and take appropriate corrective actions. Additionally, it provides real - time status monitoring of the protected equipment, allowing for proactive maintenance and improved system availability.
- Cybersecurity - Enhanced: Incorporates role - based access control and supports standards such as NERC CIP and IEC 62351 - 8, ensuring the security of the relay and the power system it protects. This is crucial in today's digital age, where power systems are increasingly vulnerable to cyber threats.
Application Fields
- Industrial Substations: In large manufacturing plants, refineries, and other industrial facilities, the REB670 is used to protect the busbars and associated equipment. It ensures the reliable operation of the internal power distribution system, safeguarding against faults that could disrupt production processes.
- Utility - Scale Power Grids: In transmission and distribution substations of power utility companies, the REB670 plays a vital role in protecting busbars and maintaining the integrity of the power grid. It helps in ensuring stable power supply to consumers by quickly isolating faults and preventing their spread.
- Renewable Energy Installations: For wind farms, solar power plants, and other renewable energy installations, the REB670 is used to protect the electrical infrastructure. As these installations often have unique electrical characteristics, the flexibility and adaptability of the REB670 make it an ideal choice for protecting their busbars and associated equipment.
Precautions
- Installation: Installation should be carried out by qualified electrical engineers following the detailed installation instructions provided in the product manual. Ensure proper grounding of the relay to prevent electrical hazards and interference. When mounting the relay in a rack, make sure it is securely fastened and that there is sufficient clearance around it for ventilation.
- Configuration: The protection settings of the REB670 must be carefully configured according to the specific requirements of the power system it is protecting. Incorrect settings can lead to either false tripping (unnecessary interruption of power supply) or failure to trip during a real fault. It is recommended to perform a thorough site - specific study and consult the product documentation or ABB technical support for accurate configuration.
- Communication Setup: When connecting the REB670 to other devices via communication interfaces, ensure that the communication protocols are correctly configured. Check for proper cable connections and signal integrity. In case of using wireless communication, take appropriate measures to ensure data security and prevent interference.
- Maintenance: Regularly perform visual inspections of the relay for any signs of physical damage, such as cracked enclosures or loose connections. Periodically test the protection functions using appropriate test equipment to verify their proper operation. Update the firmware of the relay as recommended by ABB to benefit from the latest features, bug fixes, and security enhancements.
- Environmental Conditions: Install the REB670 in an environment that meets its specified temperature, humidity, and dust - resistance requirements. Avoid exposing it to extreme temperatures, high humidity, or corrosive gases, as these can affect its performance and lifespan. If the relay is installed in a harsh environment, consider using additional protective enclosures or environmental control measures.
The structure and details of the product:

Please make an inquiry for more models
ABB TB815
ABB PP815
ABB PP820
ABB PP825
ABB PP826
ABB PP835 3BSE042234R2
ABB PP836
ABB PP845 3BSE042235R1
ABB PP846
ABB PP865
ABB PP871
ABB PP874 6.20
ABB PP877 3BSE069272R2
ABB TK854V030
ABB CB801
ABB CB810
ABB RX835
ABB RX865
ABB 07KP93B
ABB 07KR228
ABB 07KR264dR1
ABB 07KR264b
ABB 07KR220dR1
ABB 07KR220R1
ABB 07KR240R2
ABB 07KR240bR2
ABB 07KR228R2
ABB 07KT51
ABB 07KR51-A
ABB 07KR31
ABB 07KT31
ABB 07KP96
ABB 07KR91
ABB 07KP90
ABB 07KT93
ABB 07KP92
ABB 07KP92E1
ABB 07KP94
ABB 07KP95
ABB 07KT94
ABB DSAI303
ABB DSAI305
ABB DSAO301
ABB DSAV110
ABB DSAV111
ABB DSBB102
ABB DSBB107
ABB DSBB110
ABB DSBB110A
ABB DSBB170
ABB DSBB175
ABB DSBBN001-0
ABB DSBBN002-0
ABB DSBC110
ABB DSBC111
ABB DSBC170
ABB DSBSN001
ABB DSCA114
ABB DSCA124
ABB DSCA125A
ABB DSCA130
ABB DSCA170
ABB DSCA180B
ABB DSCA190V
ABB DSCA310
ABB DSCA325
ABB DSCI112
Other best-selling products:
--------------占位---------------